Figure 17 – Remote command unit (chrono-thermostat) and connection interface – both not
This board has two entries "remote" and "therm" to conect the chrono-thermostat into
the "remote" the user of the start (closed contact NC) and stop (open contact NO) the
boiler.
If connecting into the "thermostat" This will only change the power of the machine
between minimum output (open contact NO) and maximum power (closed contact
NC).
Note: the external command, as a rule, comes with a manual. In the case of wireless
remote control is necessary to connect the two wires as shown in the following figure:
For the wired remote control, the black and grey wires must be connected to the
receiver as shown in the following figure.
b)
Figure 18 – Wireless remote command connection
c)
included.
Colour codes:
CN - grey
N - black
C - brown
A - blue