Troubleshooting

A system fault will be indicated by an acoustic signal and one of the follow-
ing fault codes on the main display:
Display Fault
E01 E
General system failure
E02 E
Memory failure
E03 E
Overheated coil
E05 E
Temperature increase of
less than 1° every 30
seconds (or 1° every 60
seconds)
E06 E
Temperature probe not
connected (or defective)
E07 E
Failure during current
measurement
E08 E
Failure during communi-
cation with power printed
circuit board
E09 E
Overheated printed circuit
board
8

Spare parts

190.1521
190.1522
190.1523
190.1506
190.1501
190.7502
190.7503
190.1502
190.1503
190.1504
190.1001
© simatec ag
IH 240-CP/400V
IH 240-CP/460V
IH 240-P
IH 240-2
IH 240-3
IH 240-5
IH 240-6
IH 240-7
IH 240-10
IH 240-11
IH P2
Induction Heater IH 240 / IH 240-L
Action
Return heater for repair.
Return heater for repair.
Wait until the inductive coil cools.
Check the temperature probe connec-
tion. If the connection is OK, select
the 60 second interval as described
in section 6 or operate the heater in
TIME MODE.
Check the temperature probe.
Return heater for repair.
Return heater for repair.
Wait until the printed circuit board
(PCB) has cooled down.
Control Print 400V
Control Print 460V
Power Print
Yoke 100 x 100 x 570 mm
Yoke 65 x 65 x 570 mm
Thyristor
Thyristor protection board IH 240
Main switch IH 240
Set support yoke 100 x 100 x 150 mm
Set support yoke 100 x 100 x 370 mm
Temperature probe
27