Figure 2
flush with the finished wall.
6. Proceed to the wiring instructions.
Supply Wiring and Heater Installation
WARNING: Wiring procedures and connections should
be in accordance with the National Electric Code (NEC &
CEC) and local codes.
1. Insert approximately 6" (15.2 cm) of supply wire into
recess box through the desired knockout. Wire should be
rated for a minimum of 75°C (167°F)
2. Connect power supply to terminals provided marked L1
and L2. Ground wire should be secured to green wire
provided inside of the heater assembly.
WARNING: All units are factory prewired for operation
with the built-in thermostat. THIS HEATER IS NOT TO BE
USED WITH A REGULAR WALL THERMOSTAT.
3. Do a final and complete check of all wiring.
4. Attach heater by hanging heater on upper tabs then
securing at the bottom using the supplied screw.
5. Insert the air filter through the bottom slot, until it clicks
into place.
WARNING: TO PREVENT THE RISK OF FIRE OR
INJURY, DO NOT OPERATE THE HEATER UNLESS IT
IS FULLY ASSEMBLED.
!
NOTE: Prior to energizing remove all construction dirt
(plaster, sawdust, etc.) from interior and exterior of heater.
2
Securing Tabs
Retaining Screw
Washable Filter
Wiring
Temperature
Sensor
Display
Board
Operation
WARNING: This heater is factory prewired for operation
with the built-in thermostat. THIS HEATER IS NOT TO BE
USED WITH A REGULAR WALL THERMOSTAT.
CAUTION: This heater must be properly installed before
it is used.
The PCH is a Precision Comfort Heater, which maintains a
constant room temperature through the continuous addition
of heat by the blowing of air into the room based on the
setting of the thermostat. The PCH operates such that once
the room reaches the set point, the fan and heater will
continuously run at a low level, to maintain the desired
room temperature. If the temperature in the room rises,
i.e. sun coming through a window, the fan will slow further
and the temperature of the heater will reduce so that the
temperature of the room will continue to be the same.
!
NOTE: The element retains heat after shutdown, there
is a built in cool down period of 2 ½ minutes before the fan
shuts off completely.
WARNING: Should the Over Temp light come on,
disconnect power to the heater and call a licensed
electrician. DO NOT USE HEATER UNTIL THE CAUSE
OF THE PROBLEM IS DETERMINED AND FIXED.
Manual Controls
(See Figure 3 for display reference)
When power is first supplied to the PCH the Setpoint
Temperature will flash in the temperature display area. At any
time either the ✚ or – button can be pressed to have the
temperature setpoint displayed again.
A. Setting/Temperature Display
The PCH is designed to control the temperature of a room
anywhere from 32-86°F (0-30°C). By pressing the ✚ or –
will increase or decrease the desired temperature for the
room to be heated by 0.5° (in either °C or °F).
After 5 seconds the Setpoint Temperature will switch to
display the ambient temperature of the room.
!
NOTE: Pressing the ✚ and – at the same time will toggle
between °C and °F.
B. Comfort Setting
The Comfort Setting icon will be displayed when the heater
is in normal operation based on the Setpoint Temperature for
the room.
L1
G
L2
Cutout
R
Over
Temperature
Light
Control
Board
M
Motor
Heater
www.dimplex.com