UNIVERSAL COUNTER UC 300
8.1 Programming the "Un" (unit of measurement) parameter
Programming of this parameter is very important to the work in hand and to the
programmable parameters. You need to select either the metric or imperial unit of
measurement; you then only need to program the parameters of the UC 300 for the
chosen unit of measurement.
+ -
S elect
8.2 Manual programming of parameter "C" (pulses of the speed
sensor)
This parameter represents the number of pulses emitted by the speed sensor after
each 100 linear metres (or 328 feet) covered by the public works machine;
Enter the programming phase as described above and edit the value with the "+" and
"-" buttons; pressing and holding either button will speed up the editing process.
After setting the required value, press "Prog" to confirm and move on to the next
parameter.
with "Un" = 0
UC 300
+ -
Km/h
Prog.
S elect
R eset
UC 300
-
Prog.
R eset
Name of parameter:
Description:
Programmable
range:
Default value:
-
Name of parameter:
Description:
Programmable range:
Default value:
C
Pulses of the speed sensor after
every 100m covered by the
machine
20 to 999
Steps of 1 pulse
200
Un
selection of unit of
measurement
0 (=metric units) or
1 (=imperial units)
0