WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer. (Bosch Service: 800-944-2904.
B. Before servicing or cleaning the unit, switch power
off at service panel and lock service panel. This
will prevent power from being switched on
accidentally. When the service panel cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
C. Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes & standards, including fire-
rated construction.
D. Sufficient make-up air is needed for proper
combustion and exhausting of gases through the
flue (chimney) of fuel burning equipment to
prevent back-drafting. Follow the heating
equipment manufacturers guideline and safety
standards such as those published by the National
Fire Protection Association (NFPA), the American
Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local
code authorities.
E. Due to the size and weight of this unit, two
installers are recommended.
F.
When cutting or drilling into wall or ceiling, do
not damage electrical wiring or other hidden
utilities.
G. To properly exhaust air, be sure to duct air
outside. Do not vent exhaust air into spaces within
walls, ceilings, attics, crawl spaces, or garages.
H. Install this hood in accordance with all
requirements specified.
I.
Ventilator hood assembly models DAH93 and
DAH94 must be installed with blowers DHG4001UC
(included). Model DAH95 must be installed with
integral blowers DHG4001UC or DHG6001UC or
remote blowers DHG6003UC or DHG1006UC.
Other ventilator blowers CANNOT be substituted.
This unit is approved for use with residential appliances. For residential use only.
Note: The Bosch ventilation hood referred to throughout this manual is manufactured by BSH Home Appliances Corporation.

Important Safety Instructions

Read and Save These Instructions
Installation Must Comply With all Local Codes
Please Read Entire Instructions Before Proceeding

Safety Warning

Turn off power circuit at service panel and lock out
panel before wiring this appliance.
REQUIREMENT:
With internal blower: 120V AC, 60Hz. 15A Branch
Circuit.
With remote blower (DAH95 models only): 120V AC
60Hz. 15A Dedicated Branch Circuit.
For general residential kitchen ventilating use only.
DO NOT use to exhaust hazardous or explosive
materials or vapors.
Vent unit to the outside unless using recirculation kit.
Note: If using recirculation kit, refer to instructions
included with that unit.
To reduce the risk of fire, use only metal ductwork.
Tools and Parts Needed:
1. 1/2" Conduit w/ Connector
2. Blower (DAH95 models only)
3. Duct Cover (optional)
4. Ducting:
a) DAH93 and 94 models: 7" (8" is also accept able,
however a 7"-8" transition will also be required)
b) DAH95 models with remote blower: 10" (7"-10"
transition is also needed. For horizontal discharge, a
custom transition is required.)
5. 50W Par 20 Halogen Flood Light Bulbs (2), installed.
(For DAH93 models only, R20 50W Incandescent Flood
Light bulbs may also be used).
6. Duct Tape
8. Torx Head Screwdriver 9. Needle Nose Pliers
10. Tape Measure
Parts Included:
1. 4 #8 Sheetmetal Screws
2. Filters (30" models: 2, 36" models: 3)
3. Hood Canopy
4. Remote Blower "Pigtail" Adaptor (DAH95 models only)
5. 7" Transition
6. Spring Type Wire Nuts (rated for a minimum of (2)
#18ga wires and a maximum of 4 #14ga wires, UL &
CSA rated to 600V and 302º F/ 150º C.)
7. 6 (30" models) or 12 (36" models) Wood Screws
2
Caution
Warning
7. Phillips Head Screwdriver