TROUBLE SHOOTING

Problem
Motors will not start.
tion.
The motors stop directly
after starting.
Pump runs but no suction.
DC Tromb 400c
DC Tromb 400a
Pump runs but poor suction. Hole in the hose.
Machine blows dust.
Abnormal sound from
machine.
2016-04-06
Fault
Machine not connected.
Incorrect fuse.
Thermal overload not set
correctly.
Hose not connected.
Hose plugged.
No plastic sack on the
cyclone.
The container is not fi rmly
attached to the bottom of
the cyclone.
Plugged fi lter.
Hose too long or too small. Change the hose.
Hose is kinked.
Machine top is mounted
incorrectly.
Dust is packed in the
cyclone.
One of the fans is turned
off.
Filter is perforated or has
come loose.
DC Tromb 400- 14
Solution
Make sure connec-
Change to correct circuit.
Electrician should adjust.
Connect the hose.
Find and remove block.
Mount the correct sack.
Secure the container.
Change or repair hose.
Clean or change fi lter.
Check and free.
Adjust the mounting.
Take off the top and clean
out.
Start it.
Check the fi lters and change
if necessary.
Order service.
Part No 9480-B