INITIATING THE COOLANT CIRCULATION
When using the product for the first time or after completely emptying the coolant tank, the following procedure must be followed to start the
circulation:
- Fill the tank to its maximum level with coolant.
- Connect the coolant starting kit to the cold liquid connector on the unit (blue connector). Place the other end of the kit in an empty container.
- Switch on the liquid pump. To activate it, depending on the products, it will be necessary to connect a torch and then push the trigger, or simply
turn on the device.
- The pump should start instantly and the liquid should flow into the container. If the pump still does not start, cut off its supply, inject compressed
air into the starting kit to remove the liquid from the pipes and then restart the pump.
- Once the liquid starts flowing, the pump is running. Turn off the unit, disconnect the staring kit, refill the coolant in the tank and connect your
system to the liquid connectors on the unit. Your cooling unit is ready to be operated.
FLOW SENSOR WIRING (EXAMPLE WITH A MIG TORCH)
1
3
Disconnect one wire of the trigger.
5
7
Connect the 2 wires of the control cable to the 2 wires of the trig-
ger with 2 extensions (51441) supplied with the MULTICOOL.
9
Connect the control cable connector to the MULTICOOL connector
12
MULTICOOL 1300
Remove the washer.
Strip these 2 wires.
2
Open the housing.
4
Cut the 2 wires flush to the terminals.
6
Put the cable supplied with the MULTICOOL into the torch sheath.
8
Close the housing and replace the washer.
The torch trigger will only have an effect if the MUL-
TICOOL sensor detects a flow.