Fault Finding - Husqvarna TS 100 R Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
Maintenance
11
(the motor must be stopped)
Before carrying out any operation
disconnect the machine from the
mains
• Clean the machine daily.
• The tables can be removed for ease of cleaning
(SEE FIG. 4c).
- Tilt the motor to the bevelling position.
- Grip the large table 14a on both sides.
- Pull the safety latch 27.
- Lift the tables by pushing the assembly halfway
along their travel and lifting the large table to
remove it from the blocking point before the port.
Pull the assembly and remove the small table's
rear support 14b. Remove the tables.
- To re-insert the tables, position the small
table's rear support in its port and fold the
assembly until the large table's front support can
be lowered when its port is open.
Fully free the motor (in bevel position)
to remove and replace the tables. Do
not put your hands between the two
tables.
• Empty regularly the tank to remove muddy
deposits which could clog the pump and thus
cause premature wear.
• Wash the tray with plenty of water.
• Clean the pump.
• Store in a dry place
• Clean the rails with particular attention: we
advocate the use of a slide polish, type Loctite
VG 26.
Store in a dry place, not accessible to
children.
Maintain the tools carefully.

FAULT FINDING

In the event of faulty operation refer to the tables
below to find a solution.
• The machine does not work
CAUSES
Not
plugged
in
properly
or
cable
damaged
No mains voltage
Switch
defective,
motor cable damaged
Motor
faulty
(no
power, unpleasant
smell)
• Difficult starting
CAUSES
Single phase motor
starting condenser
Three-phase supply
not correct (on 2
phases, motor cable
faulty)
• The pump does not start
CAUSES
The mains lead is not
correctly connected or
is damaged
No voltage in pump
circuit or mains supply
circuit
• The pump does not pump water
CAUSES
An air bubble may
have formed inside
the pump body
The turbine is jammed
REMEDIES
- Make sure that the
supply is correctly
plugged in (plug,
extension lead, etc)
- Check the supply
cable
- Test or have tested
by an electrician
(circuit breaker, plug,
etc)
- Have tested by an
electrician or contact
the
service
department
- Contact the service
department to have
the motor replaced
REMEDIES
- Replace
the
condenser
- Have it checked by
an electrician or
contact the service
department
REMEDIES
- Check the mains
lead
- Check the pump
circuit and mains
supply circuit
REMEDIES
- Holding the pump of
the outlet pipe remove
it from the water and
reimmerse it
- Unscrew the filter
and, using a small
screwdriver, remove
all dirt from the
operating area of the
turbine.
27
Tabla de contenido
loading

Tabla de contenido