HEIDENHAIN IK 5000 QUADRA-CHEK Manual De Instrucciones página 19

Ocultar thumbs Ver también para IK 5000 QUADRA-CHEK:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Preparing PC
See the PC manufacturer's documentation for
enclosure access instructions.
Shut down the PC
Disconnect the power cord from the PC
Open the PC enclosure
Remove any covers or panels to gain access to the
motherboard PCIe expansion slots
Removing flyout blanks
Save the bracket screws. The bracket screws
are required for installing the IK 5000 card and
flyouts.
Remove flyout blanks from the PC to accommodate
the flyouts required for the specific IK 5000 QUADRA-
CHEK system
Setting interpolation
X, Y, Z, and Q 1 Vpp encoder signals are interpolated.
Interpolation can be changed by the DIP switch settings
on the IK 5000 QUADRA-CHEK card.
Interpolation DIP switches
Use the point of a small screwdriver to change DIP
switch settings to the desired interpolation
For interpolation options, refer to the "Interpolation
settings" table below.
Interpolation settings
Possible settings for each switch pair (3-4, 7-8) using
switch pair 3-4 as an example pair:
3 4
X20 Interpolation
3 4
X50 Interpolation
HEIDENHAIN | IK 5000 QUADRA-CHEK | 7/2016
On
Off
3 4
X25 Interpolation
3 4
X100 Interpolation
Setting output voltage
X, Y, Z, and Q output voltage can be set to 10 V or 12 V.
Output voltage can be changed by the jumper switch
settings on the IK 5000 QUADRA-CHEK card.
Output voltage jumpers
Remove the jumper
Place the jumper in the desired output voltage setting
position
For settings options, refer to the "Output voltage settings"
table shown below.
Output voltage settings
Possible settings for each jumper pair using the Q pair
as an example pair:
12 V output (default)
Setting probe trip point
The probe trip point can be set to 2.5 V or GND. The trip
point setting can be changed by the jumper switch on the
IK 5000 QUADRA-CHEK card.
Probe trip point jumper
Remove the jumper
Place the jumper in the desired probe trip point setting
position
For settings options, refer to the "Probe trip point settings"
table shown below.
Probe trip point settings
Possible settings for the probe trip point jumper:
2.5 V trip point (default)
On
Off
10 V output
GND trip point
21
Tabla de contenido
loading

Tabla de contenido