Cable Calibration - Telwin DOCTOR CHARGE 50 Manual De Instrucciones

Ocultar thumbs Ver también para DOCTOR CHARGE 50:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
SELECTION BUTTONS
STANDARD SUPPLY
The battery charger is supplied with output cables
and clamps for connecting it to the battery terminals.
OPTIONAL ACCESSORIES
Support bracket for the battery charger and cables.
For LCD DISPLAY models only, 6 m and 10 m
output cables complete with clamps are available.
LCD DISPLAY MODEL - OPTIONAL
WALL SUPPORT
CHARGING CABLES
6m
KEYPAD MODEL - OPTIONAL
WALL SUPPORT

2.1.1 CABLE CALIBRATION

(required for LCD DISPLAY models only): the
possibility of using different length charging cables
requires initial calibration so as to compensate the
drops in voltage along the cables.
CALIBRATION PROCEDURE
- press and hold the VOLT button (fig. A.21) and
plug the cable into the mains socket;
6V
12V
24V
3 sec.
BOOST
START
FULL
DESULFATION
10m
- continue to hold the VOLT button (fig. A.21) until
the digits "3 m" or "6 m" or "10 m" flash on the
display;
- select the required value using the FUNCTION
button (fig. A.22);
- wait 5" for the selection to be confirmed.
INITIAL CONDITION
KEEP PRESSED THE BUTTON "VOLT" AND
PLUG IN TO MAINS SOCKET, RELEASE
BUTTON "VOLT" AFTER 7".
7"
CABLE CALIBRATION
7"
- 18 -
DEVICE OFF
+
230V - 1ph 50/60 Hz
DISPLAY
BEEEP
DISPLAY