14.3

Storage

Clean thoroughly all components before storage.
Store all components separately in a dry area at not less than -10 ° C.
Charge the battery fully before storing.
During longer standstill but at least after one month charge the battery.
14.4

Disposal

Do not dispose the machine and the battery in residual waste. Contact your local authorities
for information regarding the available disposal options. When you buy at your local dealer
for a replacement unit, the latter is obliged to exchange your old.
15

TROUBLE SHOOTING

BEFORE YOU START WORKING FOR THE ELIMINATION OF DEFECTS, UNPLUG THE BATTERY.
Trouble
No electrical support
No charging of battery
ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
ZI-EWB500LI-AKKU
NOTICE
Possible cause
 Battery is not charged
 Motor stucks
 Power switch is damaged
 Broken or loose cables
 Loosen cable
TROUBLE SHOOTING
Solution
 Recharge battery
 Check motor
 Check switch
 Check cables
 Check cable connection