8. TECHNICAL DATA

MultiPlus Compact
PowerControl / PowerAssist
Transfer switch (A)
INVERTER
Input voltage range (V DC)
Output
Cont. output power at 25°C (VA)
Cont. output power at 25°C (W)
Cont. output power at 40°C (W)
Cont. output power at 65°C (W)
Peak power (W)
Maximum efficiency (%)
Zero-load power (W)
Zero load power in search mode (W)
CHARGER
AC Input
Charge voltage 'absorption' (V DC)
Charge voltage 'float' (V DC)
Storage mode (V DC)
Charge current house battery (A) (4)
Charge current starter battery (A)
Battery temperature sensor
GENERAL
Programmable relay (5)
Protection (2)
Common Characteristics
ENCLOSURE
Common Characteristics
Battery-connection
230 V AC-connection
Weight (kg)
Dimensions (hxwxd in mm)
STANDARDS
Safety
Emission / Immunity
Automotive Directive
12 Volt
C 12/800/35
24 Volt
C 24/800/16
Yes
800
(3)
700
650
400
1600
92 / 94
8 / 10
2 / 3
Input frequency: 45 – 65 Hz
35 / 16
Material & Colour: aluminium (blue RAL 5012)
EN55014-1, EN 55014-2, EN 61000-3-3
C 12/1200/50
C 24/1200/25
Yes
16
16
9,5 – 17V
19 – 33V
Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
1200
1000
900
600
2400
92 / 94
8 / 10
2 / 3
Input voltage range: 187-265 VAC
14,4 / 28,8
13,8 / 27,6
13,2 / 26,4
50 / 25
4
yes
yes
a - g
Operating temp. range: -40 to +65°C
(fan assisted cooling)
Humidity (non condensing) : max 95%
Protection category: IP 21
Battery cables of 1.5 meter
G-ST18i connector
10
375x214x110
EN 60335-1, EN 60335-2-29
2004/104/EC
C 12/1600/70
C 24/1600/40
Yes
16
1600
1300
1200
800
3000
92 / 94
8 / 10
2 / 3
Power factor: 1
70 / 40
25