Direct programming of intercom call

• •
Step 1: enter programming mode
Operator 1 and Operator 2 carry out the following procedures
on 2 internal units:
»The internal unit emits 1 tone.
»The red LED flashes.
»The blue audio LED lights up.
»The internal unit enters audio mode.
»At this point the 2 operators will be communicating with each
other.
Step 2 (optional): intercom audio volume adjustment
A
»The internal unit emits 1 tone.
»The blue lock-release LED flashes.
»The monitor memorises the audio setting for intercom calls.

Programming reset

Take note of the S2, S1 setting and restore it when programming is complete
1)
DIP
DIP
S1
1
2
DIP ON
1
1
Factory settings:
30
30
____
2)
DIP
DIP
DIP
DIP
S2
3
4
5
6
1
1
1
1
Step 3: intercom call programming
Operator 1:
»The internal unit manned by operator 1 emits a confirmation tone.
Operator 2:
»The internal unit manned by operator 2 emits a confirmation tone.
Operator 1/Operator 2:
»The blue audio LED switches off.
»Programming of the 2 internal units is now complete.