Parameter Settings - Baxi ECO COMPACT Manual Para El Usuario

Ocultar thumbs Ver también para ECO COMPACT:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68

14. PARAMETER SETTINGS

To set the boiler parameters, press
display shows "F01" alternated with the value of the parameter.
Edit parameters
• To scroll the parameters press
• Press
buttons to change the single parameter value;
• Press
to save changes, the display shows "MEM";
• Press
to leave the function without saving, the display shows "ESC".
ALL MODIFIED PARAMETERS SHOULD BE NOTED DOWN IN THE TABLE AT THE END OF THIS MANUAL.
Parameter
F01
Boiler type 010=airtight chamber
F02
Gas used 000=NATURAL GAS - 001=LPG - 002=gas G25.1
Hydraulic system
000 = instantaneous appliance
F03
003 = appliance with external storage boiler
004 = heating only appliance
Setting programmable relays 1
F04 - F05
000=no associated function
Maximum heating setpoint setting (°C)
F06
000=85°C (Burner goes out at 90 °C)
001=45°C (Burner goes out at 50 °C)
F07
DHW
inlet
priority configuration
F08
CH max. output (0-100%)
F09
DHW max. output
F10
CH and DHW min. heat output
Delay prior to new ignition in CH mode
F11
000=10 seconds - 001...010 = 1...10 minutes
F12
Identification of boiler model
Pump overrun time in heating mode
F13
000=10 seconds - 001...240 = 1...240 minutes
Test of correct DHW probe position 000=Disabled - 001=Always
F14
enabled
F15
Factory
setting
Anti-legionellosis function
F16
000 = Disabled - 055...067 = Enabled (setpoint 55...67°C)
F17
Hydraulic pressure switch configuration
F18
Release parameters for SERVICE
Parameter
Description of parameters
F19
Factory
F20
Factory
F21
Factory
F22
Factory
F23
Factory
F24
Factory
F25
Factory
F26
Factory
F27
Factory
F28
Factory
F29
Factory
F30
Factory
F31
Factory
F32
Factory
F33 - F34
Factory
F35
Factory
F36
Factory
and
together and hold down for at least 6 seconds. When the function is activated, the
;
Description of parameters
and 2
(See SERVICE instructions)
(0-100%)
(0-100%)
Factory settings
14 F - 1.14 F - 18 F
24 F - 1.24 F
setting
001
setting
000
setting
030
setting
110
setting
010
setting
005
setting
000
setting
165
setting
010
setting
070
setting
020
setting
000
setting
180
setting
170
setting
004
setting
015
setting
020
14 F
000
50
(60 LPG)
(60 LPG)
100
(60 LPG)
009
Parameter
Description of
parameters
F44
Factory
F45
Factory
F46
Factory
F47
Factory
F48
Factory
F49
Factory
F50
Factory
F51
Factory
F52
Factory
F53
Factory
F54
Factory
F55
Factory
F56
Factory
F57
Factory
F58
Factory
37
Factory settings
1.14 F
18 F
24 F
010
000 - 001
004
000
000
000
000
000
50
55
100
(60 LPG)
50
100
100
000
003
009
008
007
003
000
000
000
001
000
Factory settings
14 F - 1.14 F - 18 F
24 F - 1.24 F
setting
000
(this value depends on
setting
valve calibration)
setting
015
setting
000
(this value depends on
setting
valve calibration)
setting
105
setting
100
setting
005
setting
020
setting
100
setting
000
setting
003
setting
025
setting
000
setting
000
7110102.03 (1-06/13)
1.24 F
004
100
100
007
Tabla de contenido
loading

Tabla de contenido