Parameters Reset; Operating Logic - Aprimatic R1-24 Instrucciones Para La Instalación, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

4.4

PARAMETERS RESET

If you wish to restore all programmable parameters to their factory settings (default) then a RESET procedure must be
performed using one of the following methods (A or B):
A:
Switch OFF the power supply.
Press and hold the BLUE button and switch ON the mains power supply at the same time
display. The self-teach procedure must be performed, therefore:
Press and hold the YELLOW and BLUE buttons simultaneously for a few seconds and then start the procedure by
pressing START.
OR
B access the BASIC programming menu:
scroll through the parameters and confi rm
fl ashes on the display. The self-teach procedure must be performed, therefore:
Press and hold the YELLOW and BLUE buttons simultaneously for a few seconds and then start the procedure by
pressing START.
5.1

OPERATING LOGIC

During the operating cycle the system handles the following signals:
STOP pulse and START pulse.
Photocell for closing safety.
Opening safety device (photocell, safety edge ...).
Detection of any obstacle on the opening and closing strokes.
Operation of the automation functions in response to these signals depends on the operating mode selected.
Depending on the default settings (factory) the system operates with automatic logic.
The next section describes the other operating modes and
the signal responses for each operating mode.
AUTOMATIC MODE (default mode) (
Starting with the gate closed, the complete operating
cycle is as follows:
START pulse
wing 1 starts to open;
Wing 2 starts to open (if fi tted);
When both wings are opened as far as the mechanical
stop or limit switch, the gate will stay open for the
programmed pause time;
Next, wing 2 (if fi tted) will start to close.
After the preset delay time, wing 1 will start to close.
During the opening cycle, START pulses will be ignored and
signals from closing photocells will also be ignored.
During the closing cycle, any START pulses or signals from
closing photocells will trigger reopening of the wings.
During the pause time with the gate open, the closing
photocells will keep the gate stopped and open until they
are uncovered.
1
4-STEP MODE (
)
Starting with the gate closed, the complete operating cycle
is the same as that for the automatic mode.
If a START pulse is not given within the fi rst 3 seconds
of the opening pause
automatically.
If a START pulse is given within the fi rst 3 seconds of
the pause time
the gate will stay locked in the open
position; to close the gate in this case you must give the
START pulse again.
SUPER AUTOMATIC MODE (
Starting with the gate closed, the complete operating cycle
is the same as that for the automatic mode.
The START pulse in any stage of a movement
reverses the direction of movement of the gate; it will be
possible to close the gate using the control.
PSET
0
.)
the gate will start to close
2
)
by pressing and holding the RED button for 3 seconds
Automatic logic:
1
gate closed
2
1
- 29 -
Reset - Functioning logic
Lrn
"
" fl ashes on the
START pulse
gate open
2
3"
3
gate opening
pause time
4
gate closing
1
2
Lrn
"
"
Fig. 8
Tabla de contenido
loading