Flexim WI-400 Manual Del Usuario página 69

Idiomas disponibles
  • ES

Idiomas disponibles

Supplement to operating instruction - ENGLISH
Fig. 4.16:
Installation of the jaw (B)
1 – screw
Fig. 4.17:
Jaw (B) in the distance I
• Place the jaw and the guiding rods on the pipe, see Fig. 4.18.
• Position the jaw opposite the chain support.
Fig. 4.18:
Positioning on the pipe
1 – chain support
• Push the chain into the hooks of the jaw (inner cog), see Fig. 4.12.
• Place the chain around the pipe and the opposite chain support and tighten it.
• Push the end of the chain into the second hook of the jaw.
• Fix the chain, jaw and chain support on the pipe by slightly tightening the nuts, see Fig. 4.19.
• Check whether the distances a1 and a2 are the same, see Fig. 4.20. The following must be true for the distances: a1 = a2.
• Rotate the installation through 180°, see Fig. 4.21.