Replacement Parts; Disposal Instructions - Grohe F-digital Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
Functions of the digital diverter , see fold-out page III, Fig. [9].
Button
Description
Digital diverter
The buttons are assigned to the points of discharge 1 - 2 - 3. After that
comes 0 (point of discharge closed). Pressing the button symbol
starts the water flow at the corresponding point of discharge.
The buttons are assigned to the points of discharge as follows:
- Press button to be occupied.
- Pressing and holding the button to be occupied once again
changes to the next point of discharge.
- Save by pressing the button to be occupied.
Maintenance
Inspect and clean all components and replace if necessary.
Disconnect voltage supply.
Close isolating valves.
Disconnect all plug-in connectors, see fold-out page II, Fig.
[6].
I. Change digital controller/diverter batteries, see fold-out
page III, Fig. [10].
Batteries which are almost discharged are indicated by
shortened signals of the illuminated ring after pressing a
button. Batteries must be changed at the latest when signals
are no longer detected.
Lever off base and change all batteries, see Technical
product information for the digital controller/diverter. Insert
batteries with correct polarity.
Assemble in reverse order.
II. Thermostatic compact cartridge, see fold-out page II,
Fig. [3] and fold-out page III, Figs. [11] and [12].
1. Remove screw (H) and detach lid, see fold-out page II,
Fig. [3].
2. Remove screw (I), see fold-out page III, Fig. [11].
3. Detach plug (J1) and remove servo motor (J).
4. Loosen screw ring (K) using a 34mm tool and remove.
5. If necessary, lever out thermostatic compact cartridge (M)
via recess (M1).
Assemble in reverse order.
Observe the correct installation position of the
thermostatic compact cartridge (M), see detail (M2).
6. Connect plug (J1) to servo motor (J).
Fault
Cause
Water not flowing
• Water supply interrupted
• Plug-in connector without contact or no
power supply
Flow rate too low
• Functional unit not adapted to local
conditions
Water too cold/hot
• Functional unit not adapted to local
conditions
No function
• No voltage supply to functional unit
• Controller not ready
Digital controller/
• Digital controller/diverter out of range
diverter flashes white
Visualisation
Water flows to the point of discharge
The water flow starts
Water flows out of the next point of
discharge
No water flow
7. Connect the voltage supply and open the cold and hot water
supply.
8. Turn regulating nut (L) until 38 °C is reached.
9. Install servo motor (J), cams (J2) must be positioned one
above the other, see Fig. [12].
III. Non-return valve (E), see fold-out page III, Fig. [11].
1. Remove the screw plug (D).
2. Remove the non-return valve (E) and filter (F).
IV. Solenoid valve (N), see fold-out page III, Fig. [13].
Detach plug (N1), remove clip (N2) and remove solenoid
valve (N).
Assemble in reverse order.
Service
In the event of problems with installation, please switch off
the voltage supply and consult a specialist installer
or the GROHE Service Hotline via email at

Replacement parts

See fold-out page I (* = special accessories).

Disposal instructions

This category of device does not belong in the
domestic waste, but must be disposed of
separately in accordance with the relevant local
national regulations.
Dispose of batteries in accordance with national
regulations.
Remedy
- Open shut-off valves, isolating valves
- Attach plug-in connectors and connect voltage
supply
- Calibrate functional unit, see section Selection
menu
- Calibrate functional unit, see section Selection
menu
- Connect voltage supply via power supply unit
- Insert batteries
- Check or change position of transceiver
8
Tabla de contenido
loading

Este manual también es adecuado para:

36 34436 352

Tabla de contenido