User Programming -Control Unit In On Mode; Setting The Clock; Cyclical Ventilation; Cyclical Ventilation Time - Duran Electronica EUROSONDELCO Manual De Usuario

Ocultar thumbs Ver también para EUROSONDELCO:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Permanently lit up :
•It indicates that the CO concentration detected is equal to or above 50 ppm -only applicable to Detectors for CO-.
•It indicates that the gas concentration detected is equal to or above 20% L.E.L. -only applicable to EXP Detectors-.
4. USER PROGRAMMING -Module Line in ON MODE-

SETTING THE CLOCK

1. Press PROGRAMMING.
"User Program." is displayed.
2. Press PROGRAMMING to enter.
"Adjust Clock" is displayed.
3. Press PROGRAMMING to adjust.
The hour is displayed blinking.
4. Press FORWARD until you reach the right hour.
5. Press ENTER to memorise.
Follow the last 3 steps to adjust the minutes and the date.

CYCLICAL VENTILATION

This menu allows to program an Automatic Ventilation every 1, 3, 6, 12 or 24 hours, without being detected a ventilation or
alarm condition by the detectors. Default programming of cyclical ventilations is "0".
1. Press PROGRAMMING.
The group number is displayed.
2. Press PROGRAMMING again.
The current ventilation interval is shown -default "0"-.
3. Press FORWARD until you reach the desired number of hours: 1, 3, 6, 12 or 24 hours.
4. Press ENTER to memorise.
5. Press FORWARD to programme the following group -if there is one and you want to program it-.
6. Press ENTER to exit.

CYCLICAL VENTILATION TIME

This menu allows the programming of the cyclical ventilation time: from 5 to 30 minutes, that will be settled for all groups in
that module line. Default programming of cyclical ventilations is 5 minutes.
1. Press PROGRAMMING.
Programmed number of minutes is displayed -default "5"-.
2. Press FORWARD until you reach the desired number of minutes: from 5 to 30 min.
3. Press ENTER to memorise.
NOTE: This function remains unoperative if EXP gases have been programmed.

READING MODE

This menu allows to program the mode in which the Module Line will show the detectors status.
• Sequential: 1, 2, 3, etc, until displaying all detectors installed.
• Maximum Reading: The display will show first the detector with highest concentration in each group or the one
programmed with the lowest number if the concentration is 000.
Default programmed reading mode is sequential, to change it proceed as follows: