Hella 8ES 004.417-061 Instrucciones De Uso página 10

9/18 amp
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
5. Disconnect the power plug
of the charger from the mains
socket and then fi rst remove the
black clamp, followed by the red
clamp from the battery.
6. The charger must be discon-
nected manually from the battery
after the charging process.
10
Quick charging 18 A
1. Connect the charger as
described above.
2. Select the Booster function
with the switch at the front.
3. Perform quick charging for a
maximum of 20 minutes.
4. Disconnect the charger as
described above.
Caution!
The charger does not stop this
process automatically. The
Booster switch must not be
used for more than 20 minutes.
Be sure to keep a 30-minute
cooling phase after each quick
charging process.
Features
Input: 230 V - 50 Hz
Output: 12 V ->9 A
(normal charging)
12 V ->18 A
(quick charging for 20 min.)
Protection: against overload,
short-circuit, and
reverse polarity by fuse
Complies with
EN 60335-2-29-2004
Charging characteristic: W
Charging of 12 V lead acid
batteries and AGM batteries,
5 Ah to 130 Ah.