Setting The Threshold Values [H-1], [H-1], [H-2], [H-2] - schmalz X-Pump SXP Instrucciones De Servicio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Schmalz X-Pump
Deactivation value for air-saving
H1
function
h1
Hysteresis of air-saving function
Activation value for air-saving
H1-h1
function

Setting the threshold values [H-1], [h-1], [H-2], [h-2]

The order of the parameters in the menu is shown in the diagram above.
 Press the <MENU> key.
 If the menu is locked, enter the appropriate PIN.
 Use the <UP> or <DOWN> key to select the desired parameter.
 Press <ENTER> to confirm the selection.
 Use the <UP> or <DOWN> key to change the value.
 Press the <ENTER> key to save the new setting.
The next parameter is now displayed automatically.
The four yellow LEDs below the display show which value is currently being set.
If the <UP> or <DOWN> key is pressed and held, the value to be changed is
incremented rapidly.
If you exit from the menu by pressing the <MENU> key after changing a value,
the new value is not saved.
4-22
Brief operating instructions
S
C H MA LZ
Activation value of output of part pre-
H2
sent
h2
Hysteresis of output of part present
Deactivation value of output of part
H2-h2
present