Above the drawing of specific application using accessories provided. For different mountings,
please contact manufacturer.
a) Before starting works, at least two flexible mechanical link arms or other form of safety stops MUST be
installed to guarantee hold and prevent accidental falling of the window in order to provide safe working
conditions.
b) Trace centrepoint X in pencil onto the window frame (Fig.7).
c) Use brackets "A" and hinge "C" (provided) (Fig.8).
d) Apply the template onto the window frame (fixed part), taking care to ensure that the axis of the
template coincides with centrepoint X traced earlier (Fig.9). Attention: for non coplanar window
frames, cut the grey part of the template along the green line and apply onto the mobile part of the
window frame, taking care to keep it in the same reference position for the X axis.
e) Bore the casement at the points indicated on the template (Fig.10).
f) Apply the brackets (A) to the window frame using flat head screws as indicated above. Check both
horizontal and vertical alignment of brackets.
g) Assemble the bracket for bottom hung windows onto the mobile part of the window frame using the
reference points indicated on the template.
h) Complete assembly between chain terminal and quick hook using the Ø4x32 pin provided and insert
into central position (Fig.11).
i) Hook the actuator onto the brackets inserting the two channels at the end of the actuator into the pins
provided.
j) Rotate the actuator 90°, bring the chain terminal up to the hinge and insert the pin into the channel of
the latter. Connect the quick hook onto the rod.
k) Perform the electrical connections according to the diagram below or the label on the feeder cable.
l) Check that the output of the chain is perfectly aligned with the bracket. In the event that this should
not be the case, loosen the fixing screws and reposition the bracket correctly.
m) Perform a complete test of opening and closing of the window frame. After closure, check that the
window frame is completely closed and check pressure against the seals.
9. ELECTRICAL CONNECTIONS
Machines have been equipped with a power connection cable which complies with safety regulations
and protection against radio disturbance.
Before performing the electrical connection consult the table below and check correspondence
between the feeder cable and the tension data on the actuator label.
110/230V~ (a.c.), 50/60Hz
If feeder cables require extending to the control button for low voltage actuators (24V
sections should be selected accordingly. Conductor sections are indicated in the table on section 7.1
(Selection of cable section).
Voltage
═
24V
(d.c.)
30
Cable
Number
length
of wires
1 m
3
1 m
2
Colour of wires
LIGHT BLUE
BLACK
BROWN
LIGHT BLUE
BROWN
═
DC), cable