Range Specifications (DCM269)
Function
DC current
AC current (50/60Hz)
Frequency
(auto-ranging)
Non-contact voltage
Range Specifications (DCM270)
Function
DC current
AC current (50/60Hz)
Non-contact voltage
4. Description
1. Jaws
2. Flashlight button
3. Rotary function switch
4. Data-hold and backlight button
5. LCD display
6. Trigger
7. DCA ZERO key
8. Non-contact AC voltage detection LEDs
9. Probe tip
5. Safety
Important information with reference to safety, consult the manual
Double insulation
This meter has been designed with attention to safety, but the user must also take care to respect the safety
prescriptions described below.
1. Do not exceed the maximum values for current or voltage measurements.
2. Use extreme caution when working with voltages in excess of 25V AC rms. These voltages are considered a
shock hazard.
3. Never operate the device if the back panel or the cover of the battery or fuse compartment is not securely in
place.
4. Input limits: 200A (AC current), ±200A (DC current)
DCM269/DCM270
Range
200A
200A
40-51Hz
51-510Hz
0.51-1KHz
100Vac to 600Vac 50/60Hz
Range
2A
80A
2A
80A
100Vac to 600Vac 50/60Hz
3
Resolution
200mA
200mA
0.01Hz
0.1Hz
0.001KHz
Resolution
1mA
100mA
1mA
100mA
Accuracy
± (2.8% + 8 digits)
± (3.0% + 8 digits)
± (1.2% + 3 digits)
input sensitivity
5A AC RMS min.
Accuracy
± (3.0% + 10 digits)
± (2.8% + 8 digits)
± (2.8% + 10 digits)
± (2.8% + 8 digits)