ENGLISH
How to Maintain
CAUTION
Turn off the switch and unplug the electrical cord
before maintenance.
Important: Improper installation of the brushroll or
brushroll belt could cause carpet or cleaner damage.
How to replace a worn belt
Warning
: Belt pulleys can become hot during normal use. To
prevent burns, avoid touching the belt pulley when servicing the
drive belt.
1. Release cam locks and remove bottom plate. Pull up on belt to
rotate it off of the motor pulley. Lift up on brushroll and remove
worn belt. Place new belt around the brushroll. Align brushroll
pulley with belt guide (Fig. 3).
2. Ensure rubber end cap cover is installed correctly (Fig. 4A). Align
end caps with slots in cleaner base. Push brushroll into base.
3. Place lower side of belt into belt guide and pull to stretch the belt
around the left side of the motor pulley. Rotate pulley to secure
the belt into the groove. Replace bottom plate and secure with the
cam locks.
How to replace bristle strips
4. Remove rubber end cap (A) from one end. Unscrew locknut (B).
Remove end cap (C) – sleeve bearing brushroll includes a shaft
washer not shown.
Remove bearing retainer (D). Push shaft (E) through opposite
end. Pull out worn bristle strip (F) with pliers. Slide in new bristle
strip of same length (rounded end first.)
Fit track on either side of the bristle strip into the brushroll slot.
Replace the second strip from opposite end of brushroll.
5. Replace shaft. Align indentation on bearing retainer with bristle
strip on both ends of brushroll. Reassemble the remainder of
brushroll and secure into the base (Fig. 2).
How to clear clog from fan chamber
6. The clear cover provides easy inspection, cleaning and
maintenance of the fan. Release two cam locks and remove
bottom plate. Remove the two screws to release the clear fan
cover.
(some models)
(some models)
Powr-Flite.com