Back-pressure from
suction point
If the Multievacuator system is
installed so that back-pressure
occurs at the point of suction, con-
veying capacity will be reduced in
comparison with the figures given
in the tables on page 29.
Correction factor
1
0,9
0,8
0,7
0,6
0,5
0,4
0,3
0.2
0,1
0
0
1000
2000

Technical data

Motors for Multievacuator.
Multievacuator type Volt / Hz
120
140
175
130
150
175
200
30
The table below gives a correction
factor for the different Multi-
evacuator models as a function of
the back-pressure from the point of
suction.
The conveying capacity for a given
system can be calculated by mul-
3000
4000
Motor output
400 / 50
1.5 kW (2.0 hp)
400 / 50
3.0 kW (4.0 hp)
400 / 50
5.5 kW (7.5 hp)
460 / 575 / 60
2.2 kW (3.0 hp)
460 / 575 / 60
4.0 kW (5.0 hp)
460 / 575 / 60
5.5 kW (7.5 hp)
460 / 575 / 60
7.5 kW (10 hp)
Back-pressure
5000 6000
(e.g. granulate)
[Pa]
Rev / min.
3000
3000
3000
3600
3600
3600
3600
tiplying the capacity given in the
tables on page 29 by a correction
factor from the table below.
Example:
If a Multievacuator 175 system
sucks a granulate with a back-
pressure of 2000 Pa, the correction
factor given in the table is 0.66.