MANUAL CONFIGURATION OF THE BASE UNIT
The default configuration of the WES-ADI base unit is as follows:
Group 1 configured as a CoSt type safety device (see previous section) that is only active during closing;
•
•
Group 2 configured as a Foto type safety device that is also active during opening;
•
Signalling low battery status by flashing the courtesy lights.
When the device is switched on with no network configured, the radio channels are scanned in order to detect the most suitable channel
for setting up the network (least interference). If no action is taken, the network is created using this channel, otherwise the radio channel
for the network can be selected manually using the following procedure:
1. Disconnect the main control unit power supply
2. Switch jumper J1 to position 2
3. Switch on the main control unit: the number of flashes from the YELLOW LED indicates the radio channel selected.
The green and red LEDs indicate the quality of the channel selected:
- red LED: unusable channel
- green LED:
single flash - medium quality
double flash – good quality
triple flash – best channel
4. Each pressing of the PROG key switches to the next channel; release the key when the desired channel is reached.
5. Disconnect the main control unit power supply
6. Switch jumper J1 to position 1
PLEASE NOTE: The channel cannot be modified after the network has been configured.
ASSOCIATING THE SENSOR WITH THE BASE
Install the sensors by following the instructions attached to the product, then proceed as follows:
To associate a sensor with group 1, proceed as follows:
1. Press the PROG button on the base unit once: the RED LED emits single flashes
2. Press and hold the sensor SET button until LED L3 flashes intensely and regularly, then release the button.
3. The base automatically exits acquisition mode and the sensor starts to transmit with a period of 15 seconds
To associate a sensor with group 2, proceed as follows:
1. Press the PROG button on the base unit twice: the RED LED emits dual flashes
2. Press and hold the sensor SET button until LED L3 flashes intensely and regularly, then release the button.
3. The base automatically exits acquisition mode and the sensor starts to transmit with a period of 15 seconds
To associate a sensor with both groups, proceed as follows:
1. Press the PROG button on the base unit 3 times: the RED LED emits triple flashes
2. Press and hold the sensor SET button until LED L3 flashes intensely and regularly, then release the button.
3. The base automatically exits acquisition mode and the sensor starts to transmit with a period of 15 seconds
PLEASE NOTE: Association must be completed within 15 seconds, otherwise the base unit exits acquisition mode.
4. On completion, close the sensor casing and tighten the screws once more.
5. Repeat the operation for the other sensors in the network. When all the sensors have been installed and associated,
close the base unit casing.
TEST
To check the device is operating properly, make sure that activating an edge or a photocell turns on the LED on the sensor and the red LED
on the base unit.
RESET BASE UNIT CONFIGURATION
To delete the configuration of a base, it is necessary to press and hold the PROG button on the base unit until the red LED starts to flash.
14