Brita Tap Manual De Instrucciones página 12

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
7.1
Technical data of the BRITA Tap
Operating pressure
cold water connection
warm water connection
flow rate
acoustics rating
WD 3010
WD 3020
WD 3030
WD 3040
WD 3050
12
ENGLISH
0.5 bar to max. 10 bar
4°C to 30°C
max. 70°C
≥ 9 L/min
Group II/-
Dimensions
Weight
(Width/Depth/
Height)
5 cm / 25.5 cm /
1.16 kg
19.1 cm
17 .3 cm / 28.4 cm /
1.52 kg
29.4 cm
17 .2 cm / 20.5 cm /
1.45 kg
36.3 cm
17 .2 cm / 23.7 cm /
1.57 kg
34.8 cm
17 .2 cm / 20.5 cm /
1.43 kg
36.2 cm
8
Troubleshooting
A No water flow
Cause:
Troubleshooting:
B No or low water flow in spite of open water intake
Cause:
Troubleshooting:
Aerator
Cause:
M18x1
Troubleshooting:
M24x1
C Leak
M22x1
Cause:
Troubleshooting:
M22x1
M22x1
D Incorrect display or incorrect settings on the electronic
cartridge exchange indicator with display
Cause:
Troubleshooting:
Water intake closed.
O pen the water intake at the upstream shut-off
valve or by closing the locking handle (3) on the
filter head. Check hoses for kinks.
Mains pressure too low.
C heck mains pressure. If the fault continues,
check the filter system and filter cartridge and
replace if necessary. Check hoses for kinks.
F ilter head not mounted in direction of water
flow / hoses wrongly connected.
D ismantle filter head and hoses and install in
direction of water flow (chapter 3.4).
Screwed connections not fitted correctly.
C heck mains pressure. Check all screwed
c onnections and mount as described in
c hapter 3.4.
B uttons pressed in wrong order or wrong
b uttons pressed.
P ress and hold the RESET button for
8 seconds.
Tabla de contenido
loading

Este manual también es adecuado para:

3-way