5
Resetting the BRITA electronic cartridge
exchange indicator
If the maximum time or volume is reached, the B RITA electronic
cartridge exchange indicator will start beeping. (chapter 5)
– then the filter cartridge should be changed (chapter 4)
– t he B RITA electronic cartridge exchange indicator has to be
reset.
a) Press the DISPLAY button briefly to activate the display.
b) Press and hold the START/RESET button for 5 seconds until a
long beep sounds.
c) The last programmed 90 or 180 day setting now appears in
the display.
d) The timer starts automatically.
6
Maintenance
Regularly check the filter system for leaks. Regularly check the
hoses for kinks. Bent hoses must be replaced.
Prior to exchanging the filter system, read the Technical
!
Data (chapter 7) and the Operating and Safety Information
(chapter 9).
Regularly clean the outside of the filter system with a soft, damp
cloth.
!
Do not use any abrasive chemicals, cleaning solutions or
astringent cleaning agents.
7
Technical data of the P 1000 cartridge
Operating pressure
Water intake temperature
operation
Ambient tem-
perature for
storage/transport
Capacity up to carbonate hardness
8.5 °dH at setting "+"
Capacity from carbonate hardness
8.5 to 17 °dH at setting "++"
Pressure loss by nominal service flow
Empty filter cartridge volume
Weight (dry/wet)
Filter system
(filter head with filter
c artridge)
Dimensions
Filter cartridge
(Width/Depth/
Height)
Installed dimensions
(vertical installation
with wall mounting
bracket)
Operating position
Water inlet connection
Water outlet connection
2 bar to max. 8.6 bar
4°C to 30°C
4°C to 40°C
–20°C to 50°C
1000 L
500 L
0.2 bar
1 L
1.0 kg/1.4 kg
117 mm/108 mm/265 mm
108 mm/108 mm/259 mm
137 mm/130 mm/265 mm
Horizontal and vertical
G3/8"
G3/8"
11
ENGLISH