Key 4 - Timers; Key 6 - Ring Tone Cadence - Fermax 4545 Manual De Instalador Y Usuario

Interface telefónico
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TELEPHONE INTERFACE

Key 4 - Timers

o
The different times that can be programmed with other different values to that programmed
by default are:
 Ring Call Time (RCT / Ring Call Time): 01..99" [30]. Maximum time that the interface
waits for the call from the street panel to be answered. In VDS, even if a time programmed
is greater than 30", the street panel will cut the call at this time.
 Door opening time (DOT / Door Opening Time): 01 .. 99" [04]. Time for the activation
of the 4+N door open.
 Conversation Time (CT / Conversation Time): 01..99" [90]. Conversation time. In VDS,
the conversation time must be set to 90 seconds to coincide with the VDS panel values.
 Divert Delay Time (DDT / Divert Delay Time): 01..99" [1]. The delay for the interior
telephone to respond to a call from the street panel before forwarding it to an external
telephone.
Note: In VDS, this must be a maximum of 30" and less time than the duration of the
call (RCT).
 Auxiliary Relay Time (ART / Auxiliary Relay Time): 00..99" [08]. The time during which
the auxiliary relay remains activated. The value 00 means bi-stable mode.
The available options are:
Key
Parameter
1
Ring Call Time (RCT / Ring Call Time)
2
Door Opening Time (DOT / Door Opening Time)
3
Conversation Time (CT / Conversation Time)
4
Divert Delay Time (DDT / Divert Delay Time)
5
Auxiliary relay time (ART / Auxiliary Relay Time)
Steps:
1. Accessing Programming mode: pick up the telephone and before 3 seconds pass, press
# # #, confi rming access to programming mode via a confi rmation tone: beep-beep-beep.
(If already in this mode this step is not necessary).
2. Press the 4 key, you hear a beep.
3. Enter the desired parameter value, values: 1...5 (1 digit). for example: 2 (door open
activation time),
a) you hear: a confi rmation beep will sound,
b) the time value, values: 00...99 (2 digits), for example: 08 (for 8 seconds),
c) and automatically you hear: beep-beep of the correctly entered data, (if incorrect you
hear: Beep-bop)
d) you hear beep-beep-beep, return to the confi guration menu.
Sequence completed: # # # (Beep-Beep-Beep) 4 (Beep) 2 (Beep) 08 (Beep-Beep) (Beep-
Beep-Beep)

Key 6 - Ring tone cadence

o
 Ring Cadence (RC / Ring Cadence): 1..9" [3]. Time interval between two consecutive
ring tones when calling from an entry panel.
Page 28

Capítulos

Tabla de contenido
loading

Tabla de contenido