Remove the two caps from burner conveyor and
fix the bracket (N) by using screws M8 (P). Than
fix the case (G) to the bracket (N).
Anchor the regulator (A) to the plate (D) using the screws (E) provided
with the regulator. Place the seal (B) between the regulator and the plate.
After wiring the cable (I) to the 4-pole connector (M) supplied with the burner,
connect cables (I) and (L) to the regulator's terminal board as shown in
the attached wiring diagram.
Insert the regulator in the case (G),
Fix the plate (D) with the special screws (C) and tighten the cable glands (H).
0006160005_201502
Connect the connectors at the ends of cables (I) and (L) to the
corresponding burner cables.