Idiomas disponibles

  • ESPAÑOL, página 24
Figure 5 – Horizontal detection of the LOCATOR (Ref. 294130)
Figure 6 –Depth detection of the LOCATOR (Ref. 294130)
5.
Cleaning instructions
Use pads soaked in alcohol, soft detergent and damp cloth to remove any dirt and grease
1.
from the product. (Note – the Locator is "not" water proof)
2.
Use a cotton cloth to clean the camera head
6.
Trouble Shooting

Troubleshooting

Problem
The unit (mini VISIOVAL
display does not turn on
No signal
Measurement of depth
Indicates:
7.
Storage
The device must be cleaned prior to long term storage
1.
2.
Store in a cool dry place
Press
Press
Possible cause
The battery is discharged
Ensure that the battery is
inserted
in
the
)
compartment of the mini
VISIOVAL.
Faulty electronic systems
Wrong frequency
LOCATOR is out of range
to return to Figure 5
Solution
Recharge the battery
battery
Check for proper placement of
battery in the mini VISIOVAL
Contact the Virax After-sales
service
Check the frequency of your
probe
and
LOCATOR's frequency in the
frequency adjustment menu
Go back so that you are above
the camera head, where the
signal is the strongest.