English
Always remove the battery before carrying out any work on the power tool.
Condition
Running time is too short
Battery jams when being inserted in power
tool / charger
Battery is not being charged even though the
light emitting diode on the charger glows
green
Light emitting diode on charger flashes red
1)
STIHL recommends a STIHL servicing dealer.
28
Cause
Battery is not fully charged
Using unsuitable nylon line
Life of battery has been reached or
exceeded
Guides / contacts dirty
Battery too hot / too cold
(1 light emitting diode on battery glows
red)
No electrical contact between charger
and battery
Fault in battery
(4 light emitting diodes on battery flash
red for about 5 seconds)
Fault in charger
Remedy
Charge the battery
Replace nylon line
1)
Check battery
and replace
Carefully clean the guides / contacts
Allow battery to cool down / Warm up
battery slowly at a temperature of 60°F
to 70°F (15°C–20°C).
Operate the charger only in enclosed
and dry rooms at ambient temperatures
between 40°F (5°C) and 105°F (5°C–
40°C).
Remove the battery and refit it again
Take the battery out of the power tool
and refit it. Switch on the power tool – if
the light emitting diodes still flash, the
battery is faulty and must be replaced.
Have charger checked by servicing
1)
dealer
FSA 65, FSA 85