Cleaning And Maintenance; Troubleshooting - cecotec HidroBoost 1600 Car&Bike Manual De Instrucciones

Ocultar thumbs Ver también para HidroBoost 1600 Car&Bike:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

  • ESPAÑOL, página 6
ENGLISH
Turn the water supply off.
Once the power and water supply are turned off, press the trigger to depressurize the
device.
WARNING:
Do not turn the water supply off before turning the motor off. Serious damage could occur
to the pump and or motor.
Do not disconnect the high-pressure hose from the machine while the device is
pressurized. To depressurize, turn motor off, turn water supply off and squeeze gun
trigger 2-3 times.
TIPS FOR EXTENDING THE PRODUCT'S SERVICE LIFE
Never operate unit without water.
Do not use the device with hot water.
Before adjusting the pulverizing nozzle's pressure (high-to-low or low-to-high) release
trigger.
Never operate unit for more than one minute without spraying water.

5. CLEANING AND MAINTENANCE

Use exclusively specific cleaning agents for pressure washers.
The machine shall be disconnected from its power source by removing the plug from the
socket-outlet during cleaning or maintenance.
Do not store the pressure washer outdoors or where it could freeze. The pump could be
seriously damaged.

6. TROUBLESHOOTING

PROBLEM
No soap suction.
28
HIDROBOOST 1600 CAR&BIKE
CAUSE
The nozzle is not at low
pressure.
The high-pressure
extension hose or hose is
too long.
The pump injector is
clogged.
The soap bottle is
clogged.
SOLUTION
Turn the nozzle to the low-
pressure position.
Remove the high-pressure
extension hose or use a
shorter one (less than 7 m).
Contact the Technical Support
Service of Cecotec.
Clean the accessory with warm
water or replace the accessory.
Tabla de contenido
loading

Tabla de contenido