Enofrigo MUSIC Serie Manual De Instrucciones página 73

Ocultar thumbs Ver también para MUSIC Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

9 DISPLAY:
shows temperature in range -50 and +150 °C with tenths resolution in range -19.9 and
19.9 °C. Display of tenths can be disabled by programming a parameter.
10 HACCP:
ON if the HACCP function is enabled. Flashes when there are new HACCP alarms sto-
red (HA and/or HF alarm shown on the display).
11 CONTINUOUS CYCLE:
ON when the CONTINUOUS CYCLE function is activated. Flashes if the activation of the
function is prevented due to external disabling or procedures in progress (e.g.: mini-
mum compressor OFF time)
13.3.2 Keypad
12 PRG/MUTE:
- Mutes the audible alarm (buzzer) and deactivates the alarm relay;
- If pressed for more than 1 second during the reception of the automatic network
address assignment request package, starts the address assignment procedure (see
paragraph Automatic serial address assignment procedure).
- If pressed for more than 5 seconds, accesses the menu for setting the type "F" para-
meters (frequent).
- If pressed for more than 5 seconds together with
the type "C" parameters (configuration) or downloading the parameters.
- If pressed for more than 5 seconds when switching the instrument ON, activates the
procedure for setting the default parameter values (to contact manufacturer company)
- If pressed for more than 5 seconds together with
manual reset (the message rES indicates that the alarm has been reset); any delays
relating to the alarms are re-activated.
13 UP/AUX/LIGHT:
- If pressed for more than 1 second, it activates/deactivates light
- If pressed together with
nuous cycle operation (the messages ccb and ccE indicate, respectively, the start and
end of the continuous cycle).
- If pressed for more than 5 seconds together with
cedure (function available, management yet to be implemented).
- If pressed for more than 5 seconds together with
manual reset (the message rES indicates that the alarm has been reset); any delays
relating to the alarms are re-activated
14 SET/MAIN TEMPERATURE
- If pressed for more than 1 second displays and/or enables setting the set point;
- If pressed for more than 5 seconds together with
the type "C" parameters (configuration).
- Pressing this button for more than 1 second together with
used to reach the parameters relating to the HACCP alarms (HA, HAn, HF, HFn).
Code CT55900010
for more than 5 seconds, activates/deactivates conti-
English - 25
, accesses the menu for setting
, resets any active alarms with
, starts the report printing pro-
, resets any active alarms with
, accesses the menu for setting
displays a sub-menu
Rev. 03 - 07/'06
Tabla de contenido
loading