Commissioning; Changing The Assembly Location; Selecting The Anchors; Assembly - Nussbaum JUMBO LIFT 3500 HFC Instrucciones De Servicio

Tabla de contenido
vate the operating lever (2) and hold it until both
drive rails are completely lowered.
(1) (Lift + Press) = Lift
(2) (Lift + Pull) = Lower
8.4

Commissioning

i
Before commissioning, a single safety inspection
must be done (use the "single safety inspection"
form).
If the lift set up is done by a specialist (factory
trained assembler) then he can also do the safety
inspection. If the set up is done by the operating
company then a specialist must be tasked with the
safety inspection. The specialist confirms seamless
operation of the lift on the set up protocol for single
safety inspection and releases the lift for use.
After commissioning, the set up protocol must
i
be completed and sent to the manufacturer.
8.5

Changing the assembly location

To change the assembly location the pre-conditions
must be met according to the assembly guidelines.
The location change is to be done according to
the following sequence.
• Move the lifting stage upwards to approx.
1,000 mm.
• Loosen and remove all hose covers.
• Loosen base plate anchors.
• Lower the lift to the lowest position.
• Disconnect power.
• If necessary, disconnect the hydraulic lines on the
operating unit only, and seal them off with blind
stoppers.
• If necessary, suction off the hydraulic oil.
• Transport the lift with the unit to the new set up
location.
• Assemble the lift according to the procedure dur-
ing assembly and anchoring before first commis-
sioning.
Use new anchors. The old anchors are
no longer fit for purpose!
i
Before re-commissioning, a safety inspection
must be done by a specialist (use the regular
safety inspection form)
78
8.6

Selecting the anchors

Anchor
Without floor cover
type
(screed/tiles)
Heavy duty anchor
Liebig/
BM 10-15/70/40
Strongtie
Fischer
FH 15/50 B
Hilti
HSL-3-G M10/40
Injection anchor
MKT
VMZ-A 75 M12-
25/145
Hilti
HIT-HY 200 with
HIT-Z M12
Fischer
Highbond FHB II-A S
M12x75/25
i
Similar value anchors and other known brands
of anchor manufacturers can be used when
considering the conditions.
8.7

Assembly

Follow the instructions enclosed in the anchor
i
packaging.
OPI_JUMBO LIFT 3500 HFC-HYMAX XX 3500 HFC_V2.4_DE-EN-FR-ES-IT
With floor
covering
(screed/tiles)
Anchor length
depends on the
floor covering
Anchor length
depends on the
floor covering
011