Technical Specifications; Operating Range; Before Operation - Garland GLS 2200 Instrucciones De Manejo

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Technical Specifications
Rated voltage
Rated frequency
Rated power consumption
Rotation
Max. blowing speed
Max. air volume
Bag volume
Weight without cable
Protection class II
The A-rated sound pressure level of the device measured in accordance with DIN 45635 Part1, Appendix D is:
Working-place-related emission value LpA :
Vibration:
These values were measured in accordance with the following standards: EN 60 335-1/A1:2004; EN 60 335-2-100:2002
This device has a radio interference suppression according to: EN 55014-1, EN 55014-2
Please wear ear protectors!
OPERATING RANGE
This Blower/Vacuum device must only be used to blow
away or vacuum dry and light materials as e.g. dry leaves,
small branches, and pieces of paper. The vacuuming of
heavy materials as e.g. metal, stones, big branches and
broken glass is expressively excluded.

BEFORE OPERATION

Unpacking
1. Take all parts out of the packaging.
2. Check all parts for transportation damages. If you
detect any damages or if parts are missing, please
contact your dealer.
Assembly
Attention ! Always pull the plug and switch the
device OFF, before you assemble the device or
replace parts.
Blowing
1. Align the grooves on the blower tube with the grooves on
the blower outlet. Push the blower tube onto the blower
outlet until it locates in the right position (Fig. A).
2. Fix the adjustable shoulder harness on the top handle,
put the blower on (Fig. B).
3. Assembly the power cord according to the picture C1,C2
Operating instruction
1. Get though the power, move the power off/on switch to
the ON position (Fig. D)
2. Adjust speed control and the speed is moderate (Fig. E)
3. Direct the blow tube toward the leaves (Fig. F)
GLS 2200
V~
230
Hz
50
W
2200
rpm
15.000 - 18.000
km/h
270
3
m
/ min.
7,5
l
45
kg
4,7
85 dB(A)
4,13 m/s
vacuum mode
1. Press the button of the blower tube downward, draw
2. Clear the tube outlet by using the brush to protect the
3. Align the blower tube lower with the grooves on the
4. Unload the Impeller Guard (Fig. K)
5. Align the blower tube with the mark "Δ", insert the
6. Put the bag hook on the cable cleat of blower tube,
OPERATION
Use the device only for applications described in the
section Operating Range.
On/off switch
1. Connect the power and move the power off/on switch
Direct the suction tube toward tree leaves and suck them
in (Fig. P).
GB-3
2
the tube out of housing (Fig. G)
tube being blocked when suck the leaves (Fig. H)
blower tube upper .Push the blower tube lower onto
the blower tube upper until it locates in the right posi-
tion (Fig. A)
blower tube to the housing, and revolve the suction
tube about 90 degree according to the fig. L2, the
hook should be locked according to the pic.L3
and insert the bag to the housing (Fig. M)
Attention! Thrown-about objects may cause seri-
ous injuries of the operator or other persons.
Always wear eye and ear protectors as well as
a proper working dress. Spectators must keep a
distance of at least 5m.
to the ON position (Fig. N).