2.3 CONNECTING TO THE WATER SUPPLY
1.
Check that the water supply pressure is in the following range: 0,05-0,9MPa. With
higher pressures, use a pressure reducer.
2.
Connect the cold water supply hose (blue screw collar) to the cold water tap with ¾
gas threaded connector, taking care to tighten firmly to prevent leaks. The water sup-
ply hose must not be kinked or crushed and must not be changed or cut. Threaded
connections must only be tightened by hand.
3.
When appliances are supplied with hot water, the intake water temperature must not
exceed 60°C and the hose with red screw collar must be connected to the hot water
supply tap.
Warning!
If the connection is made to new pipelines, or lines which have been out of use for a long time, allow a con-
•
siderable amount of water to flow out before connecting the intake hose. This prevents any sand or other dirt
from fouling the filters installed in the appliance to protect the water intake valves.
The new intake hose supplied with the appliance must be used, and the old water supply hose must not be
•
used.
2.4 CONNECTING TO THE DRAIN
1.
Insert the end of the drain hose into a drain pipe having inside diameter of at least 4 cm, at least 50 to 90 cm
above floor level, or connect it securely (using the plastic fitting on the elbow in the hose) to a sink or bathtub.
2. In all cases, check that the end of the drain hose is securely fixed to prevent the repulsive force of the water
from pushing it out of place.
Warning!
Avoid kinks or restrictions to ensure effective drainage.
•
Any drain hose extensions must be no more than 1 metre long, must be of the same diameter and must be
•
free from restrictions of all kinds.
The end of the drain hose must never be submerged in water.
•
2.5 ELECTRICAL CONNECTION
Before connecting the plug to the power socket ensure that:
1.
The electrical system voltage is the same as that stated on the nameplate on the front of the appliance,
in the zone visible when the door is open. The rated power supply and the fuses required are specified
on the nameplate.
2.
The meter, safety breakers, power supply line and power socket are rated to withstand the maximum lo-
ad required, stated on the nameplate.
3.
The power supply socket and the plug fitted to the appliance are compatible without the use of reduc-
tions, multiple sockets, adapters and extension leads which might cause overheating or scorching.
If the power supply socket is not compatible with the plug supplied, replace the socket with one of the
appropriate type.
Warning
The power plug must be accessible after the appliance has been installed.
•
It is absolutely essential to connect the appliance to earth. Connect the plug to a socket with an earth
•
connection in good working order.
The manufacturer declines all liability for direct or indirect injury or damage deriving from a non-existent
or defective earth connection. Correct electrical connection guarantees conditions of maximum safety.
This appliance is compliant with the requirements of EEC directive 89/336 of 3.5.89 (including the amend-
•
ment directive 92/31/EEC) concerning the elimination of radio-frequency disturbance.
If the power supply lead is damaged, it must only be replaced with an original spare, available from the After-
•
Sales Service.
Do not connection/disconnect the power supply plug from the socket with wet hands
•
Only disconnect the power supply plug from the socket by taking hold of the plug itself, never by
•
pulling on the lead.