I N S TA L L AT I O N I N S T RU C T I O N S
PREPARING THE INSTALLATION LOCATION
IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, threewire
or four-wire cable, 240/208 volt, 60 hertz,
AC-only electrical supply with ground.
• Minimum distance between cooktop and
overhead cabinetry is 30" (762 mm).
LCE3010SB Radiant Cooktop
Unit
A
Inch
30-27/32
mm
783
All dimensions are stated in inches and millimeters (mm).
Allow 2" (50 mm) space below the armored cable opening to clear the electric cable and allow space
for installation of the junction box on the wall at the back of the cooktop.
20
30" Min.
(762 mm)
B
C
D
21-15/32
3-3/4
28-13/16
545
95
732
• Make sure the cabinets and wall coverings
around the cooktop can withstand the
temperatures (up to 93°C [200°F]) generated by
the cooktop.
** Do not obstruct these areas!
30 inch Radiant Cooktop
F
G
E
H
Min
Min
19-5/8
29-3/8
20-1/4
13/16
498
746
515
20
4" X 8" (102 mm x 203 mm)
opening to route armored
cable if panel is present.
I
J
K
L
Max
Min
13
5-23/32
2-1/2
24
330
145
64
610