7KH FKLPQH\ XVHG WR GLVFKDUJH WKH ÀXH JDV PXVW
be made in accordance with standards UNI 10683
- EN 1856-1-2 - EN 1857 - EN 1443 - EN 13384-
1-3 - EN 12391-1 both as regards the dimensions
and the construction materials used.
DAMAGED chimneys made from unsuitable
material (asbestos cement, galvanised steel,
etc.... with a rough and porous inside surface) are
prohibited by law and affect proper stove operation.
7KH ÀXH JDV FDQ EH GLVFKDUJHG WKURXJK D WUDGLWLRQDO
chimney (Fig. 5.8) as long as the following rules are
observed:
-
check the conditions of the chimney; old
chimneys should be renovated by introducing
steel piping with suitable insulation (rock wool,
vermiculite).

WKH ÀXH JDV FDQ EH GLVFKDUJHG GLUHFWO\ LQWR
the chimney only if the latter has a maximum
cross-section of 15 × 15 cm or diameter of 15
cm and features an inspection opening.
For larger chimneys, suitably insulated steel
pipes need to be inserted on the inside (diameter
according to the length) (Fig. 5.9).
Makes sure connections to brick chimneys are
suitably sealed.
Avoid contact with combustible materials (e.g.
wooden beams) and in any case insulate these
XVLQJ ¿UHSURRI PDWHULDO
,I WKH ÀXHV UXQ WKURXJK ZRRGHQ URRIV RU ZDOOV
VSHFLDO FHUWL¿HG SDVVWKURXJK NLWV QHHG WR EH XVHG
available on the market.
1) Vermiculite and/or rock wool.
2) Steel pipes.
3) Closure panel.
MANUALE DI INSTALLAZIONE - cod. 00 477 0811 - 01/2013 - Palazzetti - PN - Italy
INSTALLATION
A) Chimney pot with wind protection
B) Maximum cross-section of 15 × 15 cm or
diameter of 15 cm and maximum height of 4- 5
metres
C) Seal
D) Inspection
Fig. 5.8
1
2
3
Fig. 5.9
41/144