ENGLISH
Except for the COR-IND-M 1000 F and
COR-IND-M 1500 F, which can only be
used as an Air Curtain with fresh air, the rest
of models in this range have the option of
working either with fresh or warm air.
We advise you to check that the unit is in
perfect condition when unpacking it, as any
manufacturing or quality defect is covered
by the S&P guarantee.
IMPORTANT: SAFETY GUIDELINES
The appliance must not be right above or
below a socket.
Do not cover the unit with clothes or objects
that may obstruct the airfl ow and cause
overheating.
While in operation, the connection cable
must not be in front of the air outlet.
If it is installed in the bathroom, it must be
placed so that the switches or other control
devices cannot be touched by anyone in the
bathtub or shower.
There must not be any infl ammable objects
at less than 50 cm from the unit (such as
window curtains, etc.)
Keep the inlet and outlet grilles clean. When
cleaning them, disconnect the unit from the
main supply.
Do not manipulate the unit with wet hands.
The installation work must be carried out by
an electrician.
IMPORTANT: THIS APPLIANCE MUST BE
EARTHED.
The means of disconnection from the mains
supply must have an opening distance of at
least 3 mm in all poles.
To operate the unit as an Air Curtain, the
maximum distance to the fl oor must not be
greater than 6 metres.
The minimum distance between the Air
Curtain and the fl oor must be 3 metres.
INSTALLATION:
The unit must be fi xed to a convenient
surface, and the minimum distances shown
on Fig. 1 must be kept.
To install the unit, proceed as follows:
If the spiral nuts already placed in the device
are used, the centres of the screws (M-12)
must be marked according to the table
in Fig.2 (a) and Fig.2 (b). To access the
connection cards you must open the front
grille by unscrewing the screws marked
"A" in Fig. 3. To close, follow the process in
reverse order.
ELECTRICAL CONNECTION
Fig. 4 (a) and Fig. 4 (b)
The COR-IND Air Curtains are installed
appliances. When installing these air
curtains, the standards and regulations in
force in your country must be strictly adhered
to. Within the installation an electrical
isolation switch must be present, to enable
the installer to cut all supply lines.
Connect the unit to the mains supply,
checking that the voltage and frequency are
the same as those indicated on the electrical
rating plate. Use the cables with the number
of wires and sections as indicated on the
wiring diagram for every model.
The connection can be made either through
the back or from the side of the units. In case
of connection from the side, the connections
cover must be mounted through the cable
before laying the connections.
Fix the cable with the clamp provided and
mount the front cover.
OPERATION:
REMOTE CONTROL CONNECTION. (This
control is sold separately as an accessory).
CURTAIN
MODEL
COR-IND-M 1000 F
COR-IND-M 1500 F
COR-IND-M 1000/12
COR-IND-M 1500/18
IF CONNECTING BETWEEN TWO OR
MORE AIR CURTAINS OF THE SAME
MODEL (MAX. 5 UNITS), PLEASE REFER
TO WIRING DIAGRAM IN Fig. 5 (a) and Fig.
5 (b).
NOTE:
In the case of multiple connection, the
Installer must consider the increased
number of feeders based on the number of
connected units.
8
REMOTE
CONTROL MODEL
CR-20
CR-20
CR-30
CR-30