Exchanging The Module Extension On The Vs Or In The Stand-Alone System - Aventics CMS Instrucciones De Servicio

Ampliaciones de módulo diseño b
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 195
AVENTICS | CMS, BDC, Stand-Alone | R412008961–BDL–001–AF
A
1
B
Fig. 17:
Exchanging the module extension, for ex. R412008690 with 8 valve outputs
and D-SUB connection, BDC B-design bus coupler and VS (HF03 LG or HF04)
(A) or Stand-Alone system end plate (B)
1
Hexagonal socket-head screws (M5x35 at A),
(M5x40 at B)
2
BDC B-design bus coupler
3
Seal
4
(A): E end plate with VS HF03 LG or VS HF04;
(B): SAS end plate
8.1.1 Exchanging the module extension on the
VS or in the Stand-Alone system
6
3
2
7
2
1
Disassembly, exchange, and extension
5
4
3
5
6
3
3
5
Tie rod M5
6
Module extension (here
R412008690 with 1x8 and
D-SUB
7
Retaining bracket, left (only for
BDC B-design bus couplers)