10 Technical data

Product characteristics
Fail-safe inductive sensor
Rectangular, plastics
M12 connector
Enable zone 10...15 mm; [nf] non-flush mountable
Complies with the requirements:
EN ISO 13849-1: 2015 category 3 PL e
IEC 61508: SIL 3
IEC 62061: SILCL 3
Application
Type of operation
Electrical data
Electrical design
Operating voltage
Rated insulation voltage
Current consumption
Protection class
Reverse polarity protection
Outputs
Output function
Output data
Output voltage at 24 V
Voltage drop
Short-circuit protection
Max. capacitive load CL_max
[V]
[V]
[mA]
[V]
[nF]
continuous operation (maintenance-free)
DC PNP
24 DC (19.2...30 DC)
30
< 15
III
yes
2 x OSSD (A1 and A2)
Interface type C class 0
compatible with EN 61131-2 inputs type 1, 2, 3
< 2.5; (100 mA)
yes
20
Inductive sensors