Compressed Air Supply Port; Start-Up - Blitz MW 220 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
5

Compressed Air Supply Port

The required compressed air quality according to ISO8573-1
Air quality:
Connection pressure min. 7 bar max. 10 bar
6

Start-up

20
Pressure dew point ≤ 5 °C
Filtration of all solid particles >3 microns
Observe the operating instructions.
Observe the pictograms at the unit
DANGER!
Never bring hands or feet into the Hazard area during lifting or lowering.
The stay in the Hazard area during lifting and lowering is prohibited.
DANGER!
Transport of persons is prohibited.
DANGER!
Never use the mobile wheel lift on slopes and inclines.
Use the mobile wheel lift only on leveled and supporting subsurface.
WARNING!
Operation by skilled workers only.
Use of protective equipment.
At the end of work, lower the mobile wheel lift and park it at a suitable
location.
WARNING!
Lift the load only when there is no danger to personnel.
Always observe lifting and lowering movements.
The mobile wheel lift may be operated in a technically safe condition only.
WARNING!
Do not exceed the max. permitted load capacity.
Secure the tire or wheel.
Always secure the load during transport.
Transport loads only in lowered position.
Never leave the load unattended in lifted position.
Mobile Wheel Lift
Disabling the Equipment
125920
Tabla de contenido
loading

Este manual también es adecuado para:

Mw 90

Tabla de contenido