Troubleshooting - Bosch CET8-15W Instrucciones De Funcionamiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

This section provides a list of the more frequently encountered malfunctions, their causes and correc-
tive actions. The operator or maintenance personnel can perform some corrective actions, and others
may require the assistance of a qualified Bosch technician or your dealer.
PrOBleM
Excessive air tank
pressure – safety
valve pops off
Air leaks
Air leaks in air tank or
at air tank welds
Air leaks between
head and valve plate
Air leaks from safety
valve
Knocking noise
Pressure reading on
the regulated pres-
sure gauge drops
when an accessory
is used

TROUBLE SHOOTING
SyMPTOMS
Pressure switch does not
shut of motor when com-
pressor reaches cut-out
pressure
Pressure switch cut-out
too high
Tube fittings are not tight
enough
Defective air tank
Leaking seals
Defective safety valve
Defective safety valve
Pump oil is low
Carbon build-up in pump
Regulator is not adjusted
correctly
for
accessory
being used
reSOlUTION
Set the On/Off switch to Off, if the unit
does not shut off contact a Bosch factory
service center or a Bosch authorized ser-
vice center
Contact a Bosch factory service center or a
Bosch authorized service center
Tighten fittings where air can be heard es-
caping. Check fittings with soapy water so-
lution. Do not overtighten.
Air tank must be replaced. Do not repair
the leak
Warning: Risk of bursting. Do not drill into,
weld or otherwise modify air tank or it will
weaken. The air tank can rupture or ex-
plode.
Contact a Bosch factory service center or a
Bosch authorized service center
Operate safety valve manually by pulling on
ring. If valve still leaks, it must be replaced.
Operate safety valve manually by pulling on
ring. If valve still leaks, it must be replaced.
Add 30W non-detergent oil to pump.
Contact a Bosch factory service center or a
Bosch authorized service center
It is normal for some pressure drop to oc-
cur when an accessory is used, adjust the
regulator.
Note: Adjust the regulated pressure under
flow conditions while accessory is being
used.
Tabla de contenido