FUNCTIONAL DESCRIPTION
CAUTION:
Always be sure that the tool is switched off and the
•
battery cartridge is removed before adjusting or
checking function on the tool.
Installing or removing battery cartridge
1
2
012012
CAUTION:
Always switch off the tool before installing or
•
removing of the battery cartridge.
Hold the tool and the battery cartridge firmly
•
when installing or removing battery cartridge.
Failure to hold the tool and the battery cartridge
firmly may cause them to slip off your hands and
result in damage to the tool and battery cartridge
and a personal injury.
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place with
a little click. If you can see the red indicator on the upper
side of the button, it is not locked completely.
CAUTION:
Always install the battery cartridge fully until the
•
red indicator cannot be seen. If not, it may
accidentally fall out of the tool, causing injury to
you or someone around you.
Do not install the battery cartridge forcibly. If the
•
cartridge does not slide in easily, it is not being
inserted correctly.
1. Red indicator
2. Button
3. Battery
cartridge
3
Battery protection system
(Battery cartridge with a star mark)
1
011389
The battery cartridge with a star mark is equipped with
the protection system, which automatically cuts off the
output power for its long service life.
The tool stops during operation when the tool and/or
battery are placed under the following situation. This is
caused by the activation of protection system and does
not show the tool trouble.
When the tool is overloaded:
•
At this time, release the switch trigger,
remove the battery cartridge and remove
causes of overload and then pull the switch
trigger again to restart.
When battery cells get hot:
•
If any operation of the switch trigger, the
motor will remain stopped.
At this time, stop use of the tool and cool or
charge the battery cartridge after removing it
from the tool.
When the remaining battery capacity gets low:
•
If any operation of the switch trigger, the
motor will remain stopped.
At this time, remove the battery cartridge
from the tool and charge it.
Indicating the remaining battery capacity
(Only for battery cartridges with "B" at the end of the
model number.)
015676
Press the check button on the battery cartridge to
indicate the remaining battery capacity. The indicator
lamps light up for few seconds.
5
1. Star mark
1. Indicator lamps
2. CHECK button
1
2