Programming Menu - Johnson Controls YORK DPC-1 Instrucciones De Manejo Y Mantenimiento

Termostato digital programable con comunicación
Ocultar thumbs Ver también para YORK DPC-1:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
f) Off
Press the
button alternatively until
����
OFF appears on the screen. The unit is
turned off and the word OFF, the ambi-
ent temperature, the day of the week and
the time are displayed permanently on
the thermostat display (Fig. 8).
���
���������������������
������������
Fig. 8
g) Ventilation only
This operating mode is available in the
OFF mode by pressing the
which selects the fan speed.
���
h) °C/°F scale
To change the temperature degree scale,
press the
buttons simultane-
ously.
2.- Fan
When the
button is pressed, the Adjust
mode is entered for 5 seconds. The fan sym-
bol
is flashing. Pressing de
you adjust the fan speeds (
regulation: automatic (AUTO) or in continu-
ous operation (AUTO disappear). When the
fan is set automatic (AUTO), it will operate
automatically the fan in acordance with the
compressor or heating sources. Example:
-
Automatic high speed
����
-
Fixed low speed
- You can configurate the thermostat with
only one speed (micro-switch nº 6 to
ON)
3.- Day/night selection
By pressing the
button you can select
different temperature settings for the day and
night periods (in each one of the operating
modes).
Once the thermostat is installed, the
symbol is displayed, indicating that the
temperature settings selected is for the
day period (comfort). Pressing the
button displays the
that the temperature settings is for the night
period.
Whenever this button is pressed the tem-
perature settings are alternated, in both day
and night
4.- Unoccupied selection
Pressing the
selects the unoccupied temperature setting.
Pressing the
��
desired temperature. If the
pressed in AUTO mode, the cool or heat set
points in unoccupied mode are displayed
alternatively.
If while in the adjust mode the
pressed, the temperature setting is replaced
by number 0, indicating the number of days
the unoccupied mode should last. The
and
buttons increase and decrease
the number of unoccupied days. If left at 0,
this mode is maintained indefinitely; but if a
button,
number of days beyond 0 is programmed,
the
icon flashes throughout the unoccu-
pied period, indicating its temporary nature.
Once the unoccupied period has concluded,
the thermostat will switch over to the day
period (confort), except when the air con-
ditioning mode is AUTO PROG, in which
case the occupation mode will be the mode
indicated by the time schedule profile.
��
To exit the unoccupied option, just press the
button.
5.- Reading outdoor temperature
Pressing the
outdoor temperature for 5 seconds.
6.- Ambient temperature remote sensor
option
The DPC-1 thermostat is designed to accept
a remote sensor for controlling the ambi-
ent temperature of a room other than the
one the DPC-1 thermostat is located in.
These are three remote sensor options:
- RS1, remote probe. Connected to the
inner connecting strip of the thermostat,
terminals RS1-RS2. Configure as S2.
button,
- DS1, duct probe. Connected to the inner
) and the fan
connecting strip of the thermostat, termi-
nals RS1-RS2. Configure as S3.
- AS1, average digital remote probe. Con-
nected to the inner connecting strip of
the thermostat, terminals R, B and X1.
Configure as S5, S6, S7 or S8, depending
upon number of probes installed.
7.- Graphic information
The display provides constant information
on: ambient temperature, operating mode,
day/night period and fan operation. To have
acces to information on the temperature
set points press, just once, one of the tem-
perature setting buttons. This will give us, on
screen and for 5 seconds, the temperature
set point established for the operating mode
that is visible on screen at that moment.
symbol, indicating
periods.
button for over 1 second
or
button selects the
button is
����
button is
����
button displays the
GB

Programming menu

If the
button is pressed in Normal
����
Mode, only the symbols of the different
parameters that can be programmed are
displayed on screen:
-
Clock setting (day of the week, hours
and minutes).
-
Fan setting.
-
Selection of schedule
�� �
� �� �� �� �� �� �� �� ��
profiles. A schedule profile accepts
only Comfort and Economy (Day and
Night) periods. If pin 2 of the micro-
switch is set to OFF, this option is
not displayed.
-
Select temperature setting for heating
and cooling mode in Comfort (Day)
period.
-
Select temperature setting for heating
or cooling mode in Economy (Night)
Mode.
-
Select temperature setting for heating
and cooling in Unoccupied Mo-de.
The active or selectable option will flash. The
initial option is setting the clock.
�� �
� �� �� �� �� �� �� �� ��
The active buttons are:
-
Allow selecting the active option.
-
Allow changing the selection.
-
Selects the active option.
-
Exits the Programming menu, switch-
ing the thermostat in Normal Mode.
The display will come back to Normal mode
if no button have been pushed during 30
seconds.
1- Clock setting
Allows setting the day of the week, hour
and minutes.
11
Tabla de contenido
loading

Tabla de contenido