Installation and Wiring
Safety
Before assembling and installing the PMI, please read the safety
guidelines, particularly those relating to the ATEX regulations.
Before you install or commission the system, you should refer to any
guidelines laid down by the plant manufacturer or operator.
Installation site and unit surroundings
DANGER!
Make sure that the atmosphere is not potentially explosive when you install
the PMI!
• Keep as large a distance as possible between the system and any
electromagnetic fields, particularly when frequency converters are
nearby.
• To avoid the build-up of heat, a distance of 10 cm/3.94" should be
maintained all round the unit.
• Protect the system from direct sunlight and dust.
• Do not use chemicals close to the system.
• Ensure the maximum ambient and operating temperatures are not
exceeded.
• Ensure that neither liquids nor objects can enter the system at any time.
Operating Manual: PMI v315 ATEX/PMI o315 ATEX
5 - 1