View from above
On the rear side of the hot water tank there are special channels (H1, H2) for
mounting the sensors for regulation of the system connection of the hot water tank to
other heating sources. Access to the channels is under the covering joint of the
protective covering, approximately in the middle of the tank height (marked J on the
sketch).
Insert the sensor into the channel:
- if you insert the sensor higher in the channel, the thermostat will react too fast, the
operating time of the circular pump will be shorter and the difference between the
temperature in the hot water tank and heating media after the thermostat switch off
will be higher. This means that the quantity of water in the hot water tank and its
temperature will be lower,
- if you set the sensor lower in the channel, the operating time of the circular pump
will be longer and the difference between the temperature in the hot water tank and
heating media after the thermostat switch off will be lower. This means that the
quantity of water in the hot water tank and its temperature will be slightly higher.
TC 200-1/Z TC 300-1/Z TC 300-2/Z
A
1150
1550
B
740
740
C
380
560
D
-
-
E
-
-
F
1010
1410
H
1540
1940
H*
1680
2080
I
710
880
J
770
950
HV
G 1
G 1
IM
G 1
G 1
CV
G 3/4
G 3/4
VM
G 1
G 1
TV
G 1
G 1
H1
150
200
H2
-
-
HE - Heat exchanger
HV - Cold water inflow (blue rosette)
IM - HE medium outlet (blue rosette)
CV - Circulation conduit (blue rosette)
VM - HE medium inflow (red rosette)
TV - Hot water outflow (red rosette)
H1, H2 - Channel for sensors
VZ - Air inlet
IZ - Air outlet
1550
740
560
930
360
1410
1940
2080
880
950
G 1
G 1
G 3/4
G 1
G 1
200
200
5