PROGRAMMER FUNCTION MAP
START HERE
Press and hold
for 3 seconds
ENTER
PROGRAM
TUNE
OFF
LEVL
1
If COMMS option
fitted, LEVEL C
appears between
LEVL
LEVEL P and LEVEL A
P
LEVL
C
LEVL
A
14
T o add new
program,
press
once
PROG
RUN
ADD
OFF
PROG
3
Add new
Program 3
programs at
now appears
top of existing
in list
menu
PROG
2
Start program when 'on'
selected. This locks
T o view existing
other options out
programs 1 to 31
or full?
PROG
1
Select the required
program number .
Default: 1
USED
Memory used (%)
0
Paste only appears
after a program is
EDIT
SURE
copied
3 secs
PSTE
Copies the
selected
EDIT
PROG
program
3 secs
COPY
Program
editing
PROG
EDIT
functions.
3 secs
Insert
INS
Program
editing
EDIT
SURE
functions.
3 secs
DEL
Delete
Hold the
program at
Hold the
RUN
the point it
program at
stopped
current position
HOLD
Continue the
program
from where
RUN
it stopped
ON
Reset the
Program
program at
'off' state
beginning
RUN
OFF
Select program mode
of operation
Default: off
SURE
3 secs
YES
NO
A copy of program 1 can be
pasted into another program
1
Another program has been
inserted into PROG 2
re-numbering existing
2
PROG 2 to 3
SURE
3 secs
YES
NO
FAIL
HOLD
ST.V
SP
FAIL
Options: start
program at main
CONT
SP or process
variable
FAIL
ST.V
RSET
PV
Power failure recovery
Select the starting point of
position
program after power up
Default: reset
Default: PV
PROG
3
Program 1 has
been copied to
program 3
Program 3 has been
deleted. Display
shows next program
down from top of list
PROG
2
SPRU
60 S
Options:
hours
minutes
SPRU
HOUR
Ramp rate time units
adjustment
Default: hour