Parameter Summary; Password Input - KEB COMBIVERT F4-S Serie Manual De Instrucciones

Ocultar thumbs Ver también para COMBIVERT F4-S Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

4.2 Parameter Summary

Display
Parameter
CP. 0

Password input

CP. 1
Actual frequency display -
CP. 2
Inverter status display
CP. 3
Actual load
CP. 4
Peak load
CP. 5
Rated frequency
CP. 6
Boost
CP. 7
Acceleration time
CP. 8
Deceleration time
CP. 9
Minimal frequency
CP.10
Maximal frequency
CP.11
Fixed frequency 1
CP.12
Fixed frequency 2
CP.13
Fixed frequency 3
CP.14
Max. ramp current
CP.15
Max. constant current
CP.16
Speed search
CP.17
Voltage stabilization
CP.18
Slip compensation
CP.19
Autoboost
CP.20
DC-braking
CP.21
Braking time
CP.22
Relay output
CP.23
Frequency level
1)
Value 0...24 is valid as of software version 1.1
4.3 Password Input
Adjust. range
0...9999
-
-
-
0...409.58 Hz
0...25.5 %
0.01...300 s
0.01...300 s
0...409.58 Hz
0...409.58 Hz
±0...409.58 Hz
±0...409.58 Hz
±0...409.58 Hz
10...200 %
10...200 %
0...7
150...649 V,oFF
-2.50...2.50
-2.50...2.50
0...9
0...100 s
0...25 (0...24)
0...409.58 Hz
Ex works the frequency inverter is supplied without password protection,
this means that all changeable parameters can be adjusted. After
parameterizing the unit can be barred against unauthorized access. The
adjusted mode is stored.
Locking the
CP-Parameter
Releasing the
CP-Parameter
Operation of the Unit
Resolution
1
0,1 Hz
-
1 %
1 %
0.0125 Hz
0.1 %
0.01 s
0.01 s
0.0125 Hz
0.0125 Hz
0.0125 Hz
0.0125 Hz
0.0125 Hz
1 %
1 %
1
1 V
0.01
0.01
1
0.01 s
1)
1
0.0125 Hz
Password
FUNC
Password
FUNC
ANTRIEBSTECHNIK
Factory setting
-
-
-
-
-
50.0 Hz
2 %
GB
10 s
10 s
0 Hz
70 Hz
5 Hz
50 Hz
70 Hz
140 %
200 %
0
oFF
0=oFF
0=oFF
0
10 s
2
4 Hz
ENTER
UP
ENTER
UP
33
Tabla de contenido
loading

Tabla de contenido