(8) Hook for shoulder strap
(9) Shoulder strap
(10) Collection bag (vacuum mode)
Technical Data
Leaf blower/Garden Vacuum Cleaner
Article number
Rated power input
Airflow speed, max.
Volume flow rate, max.
Shredding ratio
Collection bag capacity
Weight (blow mode)
Weight (vacuum mode)
Protection class
Serial number
The specifications apply to a rated voltage [U] of 230 V. These specifications may vary at different voltages and in country-specific models.
Noise/Vibration Information
Noise emission values determined according to EN 50636-2-100.
Typically the A-weighted noise levels of the product are:
– Sound pressure level
– Sound power level
– Uncertainty K
Vibration total values a
(triax vector sum) and uncertainty K determined according to EN 50636-2-100
h
– Vibration emission value a
h
– Uncertainty K
Blow Mode
Assembly (see figure B)
Before any work on the product, disconnect supply
u
cord from the mains.
Slide the nozzle (12) onto the motor unit. Take care not to
pinch your fingers during assembly.
Mount the safety cover (4) onto the motor unit. For this,
place the safety cover (4) into the hinge on the motor unit.
Position the safety cover (4) against the motor unit and
screw in fastening screw (3) until fully tight and clicks are
heard to secure the safety cover.
Operating (see figures C and D)
Make sure that the cable is not in your way while working.
To switch on, turn the On/Off switch (1) clockwise until it
clicks.
The airflow speed is variable. To increase the airflow speed,
turn the On/Off switch (1) clockwise.
Bosch Power Tools
(11) Button for unlocking nozzle or collection bag
(12) Nozzle (blow mode)
(13) Loop for shoulder strap hooks
W
km/h
l/s
l
kg
kg
dB(A)
dB(A)
dB
2
m/s
2
m/s
To reduce the speed, turn the On/Off switch (1) anticlock-
wise.
To switch off, turn the On/Off switch (1) anticlockwise until
it clicks.
Set the On/Off switch (1) of the product to "0" before dis-
connecting the mains voltage or pulling the mains plug.
Disassembling (see figure E)
Before any work on the product, disconnect supply
u
cord from the mains.
Press button (11) in and remove the nozzle (12).
Loosen the fastening screw (3). Remove the safety cover (4)
and store it securely.
Vacuum Mode
Assembly (see figures F and G)
English | 17
UniversalGardenTidy
3 600 HB1 0..
1800
165 − 285
160
12:1
45
3.4
4.7
/ II
see type plate on product
3 600 HB1 0..
86
98
= 2.5
< 2.5
= 1.5
F 016 L81 834 | (21.03.2019)